Online UPS
|
Features
- On Line Double Conversion - Based on Transformer
- Super Wide Input Voltage Range Without Using Battery
- High Input Power Factor and Out Power Factor 0.8
- Built in Heavy - Duty Charger
- Advance BIG IGBT Power Components
- Controlled By Fully Digitized Microprocessor
- Self Diagnosis and Protection
- Smart RS 232 Communication and Compatible with SNMP
- User Friendly Large LCD and LED Display
- Pure Sine wave Output
Technical Specifications L Plus Series
MODEL
|
L+1000 |
L+2000
|
L+3000 |
L+6000 |
L+10 |
L+10K |
L+15K |
L+20K |
|
INPUT
|
|
Voltage (Vac) |
160- 270
|
380 ± 25% |
Frequency (Hz) |
50 Or 60 Hz ± 5 % (auto sensing) |
Power Factor |
> 0.98 |
|
OUTPUT |
|
Capacity (Va/W) |
1000/800 |
2000/1600 |
3000/2400 |
6000/4800 |
10K/8KW |
15K/15KW |
20K/16KW |
Voltage (Vac) |
220 V
|
Voltage Regulation |
± 2% |
Frequency (Hz) |
± 0.01 % |
Waveform |
Pure Sine Wave, THD <3% at 0-100 load% |
Transient Response |
± 4% (100% Load Variation) |
Power Factor |
0.8 |
Transfer time
|
0 Ms |
Crest Factor |
3 : 1 |
Efficiency (AC - AC) |
> 85% |
DC Start |
Yes |
Back Up Time (full load) |
10 minutes |
|
PROTECTION |
|
EMI/RFI Filter |
10-100 KHz at 40 db,100KHz-100MHz at 70 db
|
Overload
|
30 seconds later go to bypass after overload of 110%-150%, Auto Recovery |
UPS Failure |
Go to By Pass Automatically powered by utility power |
Output Short Circuit |
Current limitation, auto shutdown, Current Breaker |
Battery |
Auto Shutdown, Current Breaker |
Over Temperature |
Go to By Pass automatically when UPS inside temperature is more than 85C |
|
BATTERY |
|
Type
|
Seal Lead Acid Battery, Maintenance Free |
Voltages (Vdc) |
48 |
96 |
192 |
Quantity (pcs) |
4 |
8 |
16 |
Charger |
1 - 5 Ah |
5 - 10 Ah |
Charging |
8 hours to 90% capacity |
|
AUDIBLE ALARM |
|
Main Failure |
Sounding every 4 seconds after main fail, after 90 seconds mute |
Overload UPS Fault |
Sounding continuously |
|
INDICATOR |
|
LCD |
Input & Output Voltage Frequency / Battery Voltage / Load % / UPS State |
LED |
AC input / By pass / Inverter / Battery / Over Load |
|
COMPUTER INTERFACE |
|
Contact Closure |
AC Fault, Low Battery, Bypass Inverter, Remote Intelligent Software |
Smart RS 231 |
Smart RS 232, SNMP (optional) |
|
ENVIRONMENT |
|
Operation Temperature |
3,500 meters maximum elevation, 0° - 40° C |
Max relative Humidity |
0 - 95% Humidity non-condensing |
Audible Noise |
Less than 55 db |
|
PHYSICAL |
|
Dimension (WxDxH) mm |
170X525X390 |
220x590x420 |
230x580x580 |
340x480x825 |
410x750x1101 |
Weight (kg) |
18.5 |
35 |
43 |
65 |
80 |
95 |
210 |
250 |
|