													Online UPS												
			 | 
Features
- On Line Double Conversion - Based on Transformer
 
- Super Wide Input Voltage Range Without Using Battery
 
- High Input Power Factor and Out Power Factor 0.8
 
- Built in Heavy - Duty Charger
 
- Advance BIG IGBT Power Components
 
- Controlled By Fully Digitized Microprocessor
 
- Self Diagnosis and Protection
 
- Smart RS 232 Communication and Compatible with SNMP
 
- User Friendly Large LCD and LED Display
 
- Pure Sine wave Output
 
 
Technical Specifications L Plus Series
 
MODEL
  | 
L+1000 | 
L+2000 
  | 
L+3000 | 
L+6000 | 
L+10 | 
L+10K | 
L+15K | 
L+20K | 
 
 | 
 
INPUT 
  | 
 
 | 
 
| Voltage (Vac) | 
160- 270 
  | 
380 ± 25% | 
 
| Frequency (Hz) | 
50 Or 60 Hz  ± 5 % (auto sensing) | 
 
| Power Factor | 
> 0.98 | 
 
 | 
 
| OUTPUT | 
 
 | 
 
| Capacity (Va/W) | 
1000/800 | 
2000/1600 | 
3000/2400 | 
6000/4800 | 
10K/8KW | 
15K/15KW | 
20K/16KW | 
 
| Voltage (Vac) | 
220 V 
  | 
 
| Voltage Regulation | 
± 2% | 
 
| Frequency (Hz) | 
± 0.01 % | 
 
| Waveform | 
Pure Sine Wave, THD <3% at 0-100 load% | 
 
| Transient Response | 
± 4% (100% Load Variation) | 
 
| Power Factor | 
0.8 | 
 
Transfer time 
  | 
0 Ms | 
 
| Crest Factor | 
3 : 1 | 
 
| Efficiency (AC - AC) | 
> 85% | 
 
| DC Start | 
Yes | 
 
Back Up Time (full load) | 
10 minutes | 
 
 | 
 
| PROTECTION | 
 
 | 
 
| EMI/RFI Filter | 
10-100 KHz at 40 db,100KHz-100MHz at 70 db 
  | 
 
Overload 
  | 
30 seconds later go to bypass after overload of 110%-150%,  Auto Recovery | 
 
| UPS Failure | 
Go to By Pass Automatically powered by utility power | 
 
| Output  Short Circuit | 
Current limitation, auto shutdown, Current Breaker | 
 
| Battery | 
Auto Shutdown, Current Breaker | 
 
| Over Temperature | 
Go to By Pass automatically when UPS inside temperature is more than 85C | 
 
 | 
 
| BATTERY | 
 
 | 
 
Type 
  | 
Seal Lead Acid Battery, Maintenance Free | 
 
| Voltages  (Vdc) | 
48 | 
96 | 
192 | 
 
| Quantity  (pcs) | 
4 | 
8 | 
16 | 
 
| Charger | 
1 - 5 Ah | 
5 - 10 Ah | 
 
| Charging | 
8 hours to 90% capacity | 
 
 | 
 
| AUDIBLE ALARM | 
 
 | 
 
| Main Failure | 
Sounding  every 4 seconds after main fail, after 90 seconds mute | 
 
| Overload UPS Fault | 
Sounding continuously | 
 
 | 
 
| INDICATOR | 
 
 | 
 
| LCD | 
Input & Output Voltage Frequency / Battery Voltage / Load % / UPS State | 
 
| LED | 
AC input / By pass / Inverter / Battery / Over Load | 
 
 | 
 
| COMPUTER INTERFACE | 
 
 | 
 
| Contact Closure | 
AC Fault, Low Battery, Bypass Inverter, Remote Intelligent Software | 
 
| Smart RS 231 | 
Smart RS 232, SNMP (optional) | 
 
 | 
 
| ENVIRONMENT | 
 
 | 
 
| Operation Temperature | 
3,500 meters maximum elevation, 0° - 40° C | 
 
| Max relative Humidity | 
0 - 95% Humidity non-condensing | 
 
| Audible Noise | 
Less than 55 db | 
 
 | 
 
| PHYSICAL | 
 
 | 
 
| Dimension (WxDxH) mm | 
170X525X390 | 
220x590x420 | 
230x580x580 | 
340x480x825 | 
410x750x1101 | 
 
| Weight (kg) | 
18.5 | 
35 | 
43 | 
65 | 
80 | 
95 | 
210 | 
250 | 
 
 
 |