Online UPS
|
Features :
- Wide Input Voltage Range
- Internal Static & Manual Maintenance bypass switch
- Redundant Parallel Architecture (up to 6 units)
- High Efficiency and Battery Care System
- Input Current Distortion < 3%, Input PF 0.99
- Multiple Operating Modes: Online, Eco, Smart active
- Intelligent automatic battery test (every 24 hours)
- Simple to install and cold start
- Manufacturing in Italy
- Multi Modul Boards
- Low Acoustic noise, fan speed regulation
Technical Data B Series
MODEL |
BM 10
|
BM 15 |
BM 20 |
BT 10 |
BT 15 |
BT 20 |
BT 30 |
BT 40 |
BT 60 |
BT 80 |
BT 100 |
BT 120 |
|
INPUT
|
|
Rated Voltage |
230 Vac or 400 Vac |
400 Vac |
Voltage range (Vac) |
-40% with 40%load, -30 load with 60% load
|
Frequency range (Hz) |
40 - 72 Hz |
Power factor |
> 0.99 |
Current harmonic distortion |
THDI < 3% |
|
BY PASS
|
|
Rated Voltage
|
230 Vac single-phase |
400 Vac three-phase |
Voltage Tolerance
|
180 - 264 Vac (selectable)
|
Rated Frequency (Hz) |
50 / 60 Hz
|
Permitted frequency range
|
± 2% (selectable from ± 1% to 5% from front panel) |
|
BATTERIES |
|
|
|
Type |
Type maintenance-free lead-acid VRLA AGM / GEL; NiCd
|
Recharge time
|
6 h
|
4 - 8 h |
|
INVERTER OUTPUT
|
|
Rated power (kVA)
|
10 |
15 |
20 |
10 |
15 |
20 |
30 |
40 |
60 |
80 |
100 |
120 |
Active power (kW)
|
8 |
12 |
16 |
9 |
13.5 |
18 |
27 |
36 |
54 |
72 |
90 |
108 |
Number of phases
|
1
|
3 |
Rated voltage
|
220-230-240 Vac
|
380-400-415 Vac selectable |
Voltage Regulate range
|
220/244 Vac
|
346/422 Vac |
Crash factor (lpeak/lmrs)
|
3 : 1
|
Voltage distortion |
<1% linear load / <3% with not linear load |
Static stability |
± 1% |
Dynamic stability |
± 3% in 10ms |
Frequency |
50/60 Hz selectable |
Overload |
110%125%150% of the rated current for 5h/10'/1' |
Frequency stability |
±0,01% on main failure ± 2% (selectable from ± 1% to 5%) with mains supply present
|
|
SYSTEM |
|
Weight |
80
|
90 |
95 |
80 |
90 |
135 |
145 |
190 |
200 |
370 |
380 |
Dimensions(wdh)(mm) |
320x930x840 |
440x850x1320 |
500x850x1600 |
750x855x1900 |
Remote signaling
|
Volt free contacts |
Remote Controls |
EPO and Bypass |
Communication |
RS232 + remote contacts + communication interface slot |
Operating temperature |
0° C - 40° C |
Relative humidity |
<95%non condensing |
Color |
Dark grey (RAL 7024) |
Noise |
<52 dBa |
<48 dBA |
<52 dBa |
<65 dBA |
Protection degree |
IP 20 |
Efficiency |
>92% in On-Line Mode, >99% in Economy Mode |
Compliance |
Safety EN 62040-1 EMC EN 62040-2 Directives 73/23-93/68-89/336 EEC EN 642040-3 |
|